You are currently viewing our board as a guest which gives you limited access to view most discussions, articles and access our other FREE features. By joining our free community you will have access to searching the forum topics, post topics, communicate privately with other members (PM), respond to polls, upload your own photos and access many other special features. Registration is fast, simple and absolutely free so please, join our community today!

  • Global announcements
No global announcements

  • Latest Posts

View the latest post Attachment(s) A/C Compressor shuts off after few minutes on heat cycle


1984 Carver AC. Salon AC is a Marine Systems Air Model CM16H
Symptom: When started on heat cycle, the unit will operate for 3 to 5 minutes. Then the compressor will shut off. About 30 seconds later, there will be an extreme spike in amperage draw and the main 100 Amp AC breaker will trip. The water pump breaker does not trip nor does the salon AC breaker. Just the main 100 Amp breaker

The Fwd and after AC units operate with no issues - its just the salon unit.

Yes, I have strong water flow out all 3 of the outflows (2 on port, one on starboard). I have opened and cleaned the pump strainer several times.

I have removed the return air vent and cleaned the filter. I tried testing by run the AC unit on heat mode with the return air cover removed and it did not change anything

When the compressor shuts down, it is not warm to the touch (I thought it might be overheating)

My marina mechanic spent a very short time troubleshooting (its haulout time where I live and he is very busy). He told me that he tested the Freon and said it was fine.

If I run the system on Cooling - I have no issues at all. Its only on the heat mode.

My marina mechanic suspects that it is the reversing valve. I had no idea what that was - so I did a bit of Google research. It seems to me that if the reversing valve were sticking - I would get no heat at all. That is not the case. When I run it on heat mode, I get heated air blowing into the salon. It runs that way for about 5 minutes and then the compressor shuts off. The air handler/blower fan continues to operate and move air. About 30 seconds later, there is a spike in amperage draw and the main 100 amp breaker trips.

I shut off the salon ac unit, reset the 100 amp breaker, and i can turn the ac unit right back on in heat mode.

Any help would be appreciated

Views: 5790  •  Comments: 11  •  Write comments [ Back ]



  •  Who is online?
  • In total there are 894 users online :: 4 registered, 0 hidden and 890 guests

    Registered users: Bing [Bot], gmac98004, Google [Bot], Google Adsense [Bot]


  •  Newest members


  •  Statistics
  • Totals
    Total posts 68141
    Total topics 8189
    Total Announcements: 0
    Total Stickies: 4
    Total Attachments: 6662

    Topics per day: 2
    Posts per day: 14
    Users per day: 2
    Topics per user: 1
    Posts per user: 6
    Posts per topic: 8

    Total members 11546
    Our newest member DandE

  •  Birthdays
  • No birthdays today
    In the next 30 days
    No members have a birthday within this period of time.

  •  Sponsors